Skip to content

Output unit of magnetic field #13

Description

@versatran01

ROS MagneticField message defines its output in Tesla.
http://docs.ros.org/jade/api/sensor_msgs/html/msg/MagneticField.html
3dm-gx4 measures magnetic filed in Gauss and the driver outputs is thus in Gauss
http://www.microstrain.com/inertial/3dm-gx4-25

The conversion between tesla and gauss is 1 Tesla = 10000 Gauss
This inconsistency is not very well documented and thus may cause confusion.

We could

  1. fix the output to Tesla, thus the output will typically range from 0 to 0.00005 Tesla, which is numerically unfavorable.
  2. keep using gauss, which contradicts with the ros definition, but we could document it in readme. Output will range from 0 to 0.5 Gauss.