profile-requestBACnet profile automation requestBACnet profile automation requestprofile:generatedProfile was mergedProfile was mergedprofile:provider:deepseekUse the DeepSeek Profile Agent environmentUse the DeepSeek Profile Agent environmentprofile:unverifiedNot verified on real hardwareNot verified on real hardwarerequirement-gatheringWaiting for profile requirementsWaiting for profile requirements
Description
Device Vendor
Eddy Solutions
Device Model
Link
Product Manual/Datasheet Link
LoRaWAN Class
Class C
LoRaWAN Protocol Version
LORAWAN_1_0_4
Uplink Data Examples
fport3: 010702080319180102 (Describe)
fport3: 020c040000001c0104b000 (Meter Data)
fport3: 030800 (Valve)
Decode Function (Optional)
Downlink Support
Yes - supports downlink commands
Downlink Command Examples (Only if Downlink Support is Yes)
Command: Close Valve
Fport: 5
Control Value: 0x01
Expected Downlink: 0x7301
Command: Open Valve
Fport: 5
Control Value: 0x00
Expected Downlink: 0x7300
Command: Set Report Period
Fport: 5
Control Value: 0x05
Expected Downlink: 0x7105
BACnet Object Mapping Requirements
Flow Rate –> Analog Input Object
- Bytes 9-10 for Payloads: 0x02, 0x04
- Bytes 3-4 for Payload: 0x82
Odometer –> Analog Value Object
- Bytes 3-6 for Payloads: 0x02, and 0x04
Report Period –> Analog Value Object
- Bytes 5 for Payload Payload: 0x01
Firmware Version –> Analog Value Object
- Bytes 1-2 for Payload: 0x01
Meter Status Byte
- Bytes 1-2 for Payloads: 0x02, 0x03, and 0x04
- Bytes 6-7 for Payload: 0x15
Valve Operation Status –> AnalogInputObject
- (Meter Status Byte 0), Bit 5-7 (Button press, Cloud Command, Steady)
Valve Status –> AnalogInputObject
- (Meter Status Byte 1), Bit 0-2 (open/close, opening/closing, error)
Minor Flow Alert –> Binary Input
- (Meter Status Byte 1), Bit 3
Major Flow Alert –> Binary Input
- (Meter Status Byte 1), Bit 4
Extreme Flow Alert –> Binary Input
- (Meter Status Byte 1), Bit 5
Valve Control –> BinaryOutputObject
- Byte 1 for Payload: 0x73
Set Report Period –> AnalogValueObject
- Byte 1 for Payload: 0x71
Priority
⚡ Medium - Planned for near-term use
Company or organization
Eddy Solutions
Pre-submission Checklist
- I have provided complete device model information
- I have provided real uplink data examples
- I have explained the meaning of data fields
- I have checked for duplicate profile requests
Metadata
Metadata
Assignees
Labels
profile-requestBACnet profile automation requestBACnet profile automation requestprofile:generatedProfile was mergedProfile was mergedprofile:provider:deepseekUse the DeepSeek Profile Agent environmentUse the DeepSeek Profile Agent environmentprofile:unverifiedNot verified on real hardwareNot verified on real hardwarerequirement-gatheringWaiting for profile requirementsWaiting for profile requirements
Activity
github-actions commentedon Sep 11, 2026
The request passed the Profile Intake gate and is queued for Profile Agent generation.
Deferred evidence checks:
A new run is bound to the current Issue body SHA. Editing the Issue cancels and replaces that run.
github-actions commentedon Sep 14, 2026
Profile Automation created or updated a Draft PR: #43
Please review the evidence matrix and required CI. The bot will never mark it ready, approve it, or merge it.
github-actions commentedon Sep 14, 2026
The generated Profile was merged in #43. It remains unverified until confirmed on real hardware.
rakaustin commentedon Sep 14, 2026
Merged Profile: profiles/Eddy-Solutions/Eddy-Solutions-Link.yaml. It remains unverified until confirmed on real hardware.